RESUMO
BACKGROUND: Cardiovascular magnetic resonance (CMR) extracellular volume (ECV) allows non-invasive detection of myocardial interstitial fibrosis, which may be related to diastolic dysfunction and left atrial (LA) remodeling in hypertrophic cardiomyopathy (HCM). While the prognostic role of LGE is well-established, interstitial fibrosis and LA dysfunction are emerging novel markers in HCM. This study aimed to explore the interaction between interstitial fibrosis by ECV, LA morpho-functional parameters and adverse clinical outcomes in selected low-risk patients with HCM. METHODS: 115 HCM patients and 61 matched controls underwent CMR to identify: i) interstitial fibrosis by ECV in hypertrophied left ventricular LGE-negative remote myocardium (r-ECV); ii) LA indexed maximum (LAVi max) and minimum (LAVi min) volumes, ejection fraction (LA-EF) and strain (reservoir εs, conduit εe and booster εa), by CMR feature-tracking. 2D-echocardiographic assessment of diastolic function was also performed within 6â¯months from CMR. A composite endpoint including worsening NYHA class, heart failure hospitalization, atrial fibrillation and all-cause death was evaluated at 2.3â¯years follow-up. HCM patients were divided into two groups, according to r-ECV values of controls. RESULTS: Patients with r-ECV ≥29% (nâ¯=â¯45) showed larger LA volumes (LAVimax 63 vs. 54â¯ml/m2, pâ¯<â¯0.001; LAVimin 43 vs. 28â¯ml/m2, pâ¯ã0001), worse LA function (εs 16 vs. 28%, εe 8 vs. 15%, εa 8 vs. 14%, LA-EF 33 vs. 49%, all pâ¯<â¯0.001) and elevated Nt-proBNP (1115 vs. 382â¯pg/ml, pâ¯=â¯0.002). LA functional parameters inversely correlated with r-ECV (εs râ¯=â¯-0.54; LA-EF râ¯=â¯-0.46; all pâ¯<â¯0.001) and E/e' (εs râ¯=â¯-0.52, LA-EF râ¯=â¯-0.46; all pâ¯<â¯0.006). r-ECV ≥29% and LAVi min >30â¯ml/m2 have been identified as possible independent factors associated with the endpoint. CONCLUSIONS: In HCM diffuse interstitial fibrosis detected by increased r-ECV is associated with LA remodeling and emerged as a potential independent predictor of adverse clinical outcomes, on top of the well-known prognostic impact of LGE.
Assuntos
Reabilitação Cardíaca , Cardiologia , Sistema Cardiovascular , Esportes , Humanos , Exercício FísicoAssuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Veias Pulmonares , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Cateterismo CardíacoRESUMO
BACKGROUND: The use of apical views focused on the left atrium (LA) has improved the accuracy of LA volume evaluation by two-dimensional (2D) echocardiography. However, routine cardiovascular magnetic resonance (CMR) evaluation of LA volumes still uses standard 2- and 4-chamber cine images focused on the left ventricle (LV). To investigate the potential of LA-focused CMR cine images, we compared LA maximuml (LAVmax) and minimum (LAVmin) volumes, and emptying fraction (LAEF), calculated on both standard and LA-focused long-axis cine images, with LA volumes and LAEF obtained by short-axis cine stacks covering the LA. LA strain was also calculated and compared between standard and LA-focused images. METHODS: LA volumes and LAEF were obtained from 108 consecutive patients by applying the biplane area-length algorithm to both standard and LA-focused 2- and 4-chamber cine images. Manual segmentation of a short-axis cine stack covering the LA was used as the reference method. In addition, LA strain reservoir (εs), conduit (εe) and booster pump (εa) were calculated using CMR feature-tracking. RESULTS: Compared to the reference method, the standard approach significantly underestimated LA volumes (LAVmax: bias - 13 ml; LOA = + 11, - 37 ml; LAVmax i: bias - 7 ml/m2; LOA = + 7, - 21 ml/m2; LAVmin; bias - 10 ml, LOA: + 9, - 28 ml; LAVmin i: bias - 5 ml/m2, LOA: + 5, - 16 ml/m2), and overestimated LA-EF (bias 5%, LOA: + 23, - 14%). Conversely, LA volumes (LAVmax: bias 0 ml; LOA: + 10, - 10 ml; LAVmax i: bias 0 ml/m2; LOA: + 5, - 6 ml/m2; LAVmin: bias - 2 ml; LOA: + 7, - 10 ml; LAVmin i: bias - 1 ml/m2; LOA: + 3, - 5 ml/m2) and LAEF (bias 2%, LOA: + 11, - 7%) by LA-focused cine images were similar to those measured using the reference method. LA volumes by LA-focused images were obtained faster than using the reference method (1.2 vs 4.5 min, p < 0.001). LA strain (εs: bias 7%, LOA = 25, - 11%; εe: bias 4%, LOA = 15, - 8%; εa: bias 3%, LOA = 14, - 8%) was significantly higher in standard vs. LA-focused images (p < 0.001). CONCLUSION: LA volumes and LAEF measured using dedicated LA-focused long-axis cine images are more accurate than using standard LV-focused cine images. Moreover, LA strain is significantly lower in LA-focused vs. standard images.